Select Help > Open Examples... from the menus and type either the example name listed above or one of the keywords below.
Or in Version 13 or higher you can open the project directly from this page using this button. Make sure to select the Enable Guided Help before clicking this button.
<script src="https://s3.amazonaws.com/downloads.awrcorp.com/gh/ghcommon.bas" type="text/awrscript"> </script> <button class="gh-button gh-projectopen" onclick="runAwrScript('awrGhOpenProject','WiMAX_Mobile_802_16e_RX.emp')">Open Install Example</button> |
Mobile WiMAX 802.16e RX Test Bench
This example demonstrates:
WirelessMAN-OFDMA Phy, compliant with IEEE 802.16e.
Specification document: 802.16e-2005.pdf, Section 8.4.
This example can be used to measure BER vs. Output Power. Other measurements, such as signal IQ, power and spectrum can also be monitored at test points before and after the RX DUT.
User-selected options include:
• Rate_ID: 0 to 6 (defines modulation and RS-CC code rate)
• UD_mode: Downlink PUSC, Downlink FUSC or Uplink PUSC
• NFFT: FFT size (2048, 1024, 512, 128)
• G: Cyclic prefix (1/4, 1/8, 1/16, 1/32)
• Nominal bandwidth (MHz)
• Carrier Frequency (MHz)
• TxOutLvlStart, TxOutLvlSpan, TxOutLvlStep (dBm): Define swept power of transmitted signal
• MinNumErrsCollect, MaxNumBlockRun: Define BER measurement settings
DB(PWR_vsT(TP.TX_Out,1,0,1,0,0,1000,0,10,0,-1,0,-1,1,0,0,0.5,0,0,0,0,0)) (us) WiMAX Mobile System Time | DB(PWR_vsT(TP.TX_Out,1,0,1,0,0,1000,0,10,0,-1,0,-1,1,0,0,0.5,0,0,0,0,0)) (dBm) WiMAX Mobile System |
---|---|
49988.6 | -99.5767 |